PXMOD Implementation

Acquisition and Data Requirements

Image Data

A dynamic PET data set.

Blood Data

The plasma activity from the time of injection until the end of the acquisition.

Optionally: whole blood activity to be subtracted from the pixel-wise TACs, loaded as Whole Blood Data in Blood Preprocessing.

Blood-related TAC

Optional. The delay and dispersion fit can be applied for brain perfusion data with [15O]-H2O scans.

Blood Preprocessing

The same blood Preprocessing steps are available as for the brain perfusion model, but except for the data definition field all options are initially disabled as shown below.

PXMOD Alpert General Blood Pre-Processing

If no whole-blood TAC is defined, the plasma curve will be used for spillover correction.

Model Preprocessing

During model Preprocessing a lookup table is calculated within a range of k2 values. The specifications include an optional TAC which is interpreted as whole-blood activity to be subtracted from the pixel-wise TACs.

PXMOD 1-Tissue Zhou Pre-Processing

vB

Blood volume fraction defining the pixel-wise blood spillover correction.

Filter
planar

Number of pixels in the smoothing filter in x and y.

Filter
axial

Number of pixels in the smoothing filter in z.

Threshold

Discrimination threshold for background masking.

Map Parameters

PXMOD Zhou 1-Tissue Model Parameters

vB

Blood volume fraction defining the pixel-wise blood spillover correction. To fit, please activate in the Preprocessing tab.

K1

K1 rate constant of 1-tissue compartment model.

k2

k2 rate constant of 1-tissue compartment model.

Vt